Blauberg KOMFORT Roto EC SKES 200 L S21

Air handling units with rotary heat exchanger
  • Power of electrical reheater: 700 W
  • Sound pressure level LpA at 3 m: 33 dB(A)
  • Heat exchanger type: Rotary
  • Extract filter: G4
  • Supply filter: G4 (F7 optional)
  • Sound-insulated casing
  • Motor type: EC
  • Bypass: Auto
  • Reheater: Built-in
  • BMS protocol: ModBus
  • Control: Smartphone
  • Casing material: Steel
  • Humidity sensor: Optional
  • CO2 sensor: Optional
  • VOC sensor: Optional
  • PM2.5 sensor: Optional
Unit of measurement KOMFORT Roto EC SKES 200 L S21
Connected air duct size mm 125
Phases - 1
Minimum supply voltage V 230
Maximum supply voltage V 230
Power supply frequency Hz 50
Rated power W 171
Power of electrical reheater W 700
Unit current A 4.31
Maximum airflow m3/h 270
Sound pressure level LpA at 3 m dB(A) 33
Heat recovery efficiency, max % 93
Heat exchanger type - Rotary
Heat exchanger material - Aluminum
Weight kg 53
Extract filter - G4
Supply filter - G4 (F7 optional)
Transported air temperature (max) °С 40
Transported air temperature (min) °С -25
Ambient air temperature min °С 1
Ambient air temperature max °С 40
Ambient air humidity max % 60
Ingress protection rating - IP22
Ingress protection rating of the drive - IP44
Blauberg KOMFORT Roto EC SKES 200 L S21 45 240 2016
Trademark Blauberg
Model KOMFORT Roto EC SKES 200 L S21
Specific energy consumption (SEC) (kWh/(m2/a)) Cold Average Warm
-85.6 A+ -41.1 A -15.6 E
Type of ventilation unit Bidirectional
Type of drive installed Variable speed
Type of heat recovery system Regenerative
Thermal efficiency of heat recovery (%) 88
Maximum flow rate (m3/h) 240
Electric power input (W) 170
Reference flow rate (m3/s) 0.047
Reference pressure difference (Pa) 50
Specific power input (SPI) (W/(m3/h)) 0.411
Control typology Local demand control
Maximum internal leakage rates (%) 3.3
Maximum external leakage rates (%) 2.7
Declared typology RVU BVU
Sound power level (dB(A)) 45
The annual electricity consumption (AEC) (kWh/a) Cold Average Warm
217 869 217
The annual heating saved (AHS) (kWh/a) Cold Average Warm
9100 4652 2104
Datasheet
KOMFORT Roto EC SKE 200 - data sheet
1.41 Mb
Manual
KOMFORT Roto EC SKE 200 - user's manual (B273EN-02)
2.83 Mb
BIM/CAD-models
KOMFORT Roto EC SKE 200
1.82 Mb
BIM/CAD-models
KOMFORT Roto EC SKE 200 L S21
524 Kb
BIM/CAD-models
KOMFORT Roto EC SKE 200 R S21
526 Kb
Image
KOMFORT Roto EC SKES 200 L S21 - image 1
338 Kb
H W W1 W2 L L1
746 596 408 173 326 338
Name Photo Description
Blauberg SD 125/600 SD 125/600 Silencers for round ducts
Blauberg SD 125/900 SD 125/900 Silencers for round ducts
Blauberg SD 125/1200 SD 125/1200 Silencers for round ducts
Name Photo Description
Blauberg VKA 125 VKA 125 Air dampers for round ducts
Name Photo Description
Blauberg S25 S25 LCD control panel
Blauberg S22 S22 Control panels
Blauberg S22 Wi-Fi S22 Wi-Fi Control panels
Name Photo Description
Blauberg CD-1 CD-1 CO2 sensors