| Unit of measurement | Ceileo 300 | ||||
| Speed | - | 1 | 2 | 1 | 2 |
| Connected air duct size | mm | 150 | |||
| Phases | - | 1 | |||
| Minimum supply voltage | V | 230 | |||
| Maximum supply voltage | V | 230 | |||
| Power supply frequency | Hz | 50 | 60 | ||
| Rated power | W | 31 | 49 | 35 | 63 |
| Unit current | A | 0.15 | 0.22 | 0.17 | 0.28 |
| Maximum airflow | m³/h | 220 | 300 | 200 | 320 |
| Rotation speed at 50hz | - | 936 | 1254 | 888 | 1320 |
| Sound pressure level LpA at 3 m | dB(A) | 28 | 31 | 27 | 32 |
| Weight | kg | 5.1 | |||
| Ambient air temperature min | °С | 1 | |||
| Ambient air temperature max | °С | 40 | |||
| Ingress protection rating | - | IPX2 | |||
| Article | - | 8048487 | |||
| Trademark | Blauberg | |||||
| Model | Ceileo 300 | |||||
| Specific energy consumption (SEC) (kWh/(m²/a)) | Cold | Average | Warm | |||
| -28.7 | B | -12.3 | E | -2.9 | F | |
| Type of ventilation unit | Unidirectional | |||||
| Type of drive installed | 2-speed | |||||
| Type of heat recovery system | None | |||||
| Maximum flow rate (m³/h) | 160 | |||||
| Electric power input (W) | 44 | |||||
| Reference flow rate (m³/s) | 0.044 | |||||
| Reference pressure difference (Pa) | 50 | |||||
| Specific power input (SPI) (W/(m³/h)) | 0.156 | |||||
| Control typology | Manual control | |||||
| Maximum external leakage rates (%) | 2.7 | |||||
| Declared typology | RVU UVU | |||||
| Sound power level (dB(A)) | 57 | |||||
| The annual electricity consumption (AEC) (kWh/a) | Cold | Average | Warm | |||
| 195 | 195 | 195 | ||||
| The annual heating saved (AHS) (kWh/a) | Cold | Average | Warm | |||
| 3355 | 1715 | 776 | ||||
| Name | Photo | Description |
|---|---|---|
| Blauberg CDP-2/10 |
|
Multi-speed switch |
| Name | Photo | Description |
|---|