Series Blauberg Smart

Smart exhaust fans with stylish design for enhanced comfort in bathrooms, shower rooms, kitchens
  • Impeller type: Axial
  • Short spigot
  • Humidity sensor
  • Motion sensor
Options

 INTELLIGENT HUMIDITY SENSOR

The fan is equipped with an intelligent humidity sensor for automatic control of natural indoor climate.

  • QUIET – the balanced humidity extraction mode that provides sufficient air flow (up to 83 m³/h) combined with silent operation. This mode is recommended for small bathrooms.
  • MAXIMAL – excessive humidity extraction mode with maximum air flow up to 133 m³/h. This mode is recommended to the bathrooms above 6 m².


 TIMER

The fan is equipped with three various timer types for the most comfortable microclimate:

  • HUMIDITY TIMER – adjustment of the operation time of the fan for total humidity removal after stabilization of its level, adjustable for 30, 45, 60 min.
  • TURN-OFF DELAY TIMER – after activation of the IR motion sensor or the external switch the fan continues operating within 5, 15 or 30 min and then revers to previous operation mode.
  • TURN-ON DELAY TIMER – if you have to visit your bathroom frequently and briefly, adjust the turn-on delay function to avoid unnecessary switching of the fan.


The fan switches to higher speed in 0, 2 or 5 minutes after the humidity level increase or activation of the IR motion sensor.

 24 HOURS

The fan runs with low speed to ensure minimum air exchange in the room. After humidity change, the fan switches to MAXIMAL (by default) or QUIET mode. After the signal from the IR-Sensor or an external switch the fan will turn to QUIET mode.


 INTERVAL VENTILATION

Integrated function of the automatic room ventilation. Each 15 hours the fan is switched on for 2 hours to ventilate the premise with the air flow 83/72 m³/h (Ø125/Ø100).


 SMOOTH SPEED CONTROL

The fan has an integrated smooth speed control function adjustable in 10 speeds:

  • for QUIET mode from 40/33 to 83/72 m³/h (Ø125/100);
  • for MAXIMAL mode from 83/72 to 133/106 m³/h (Ø125/100).


 IR MOTION SENSOR (FOR SMART IR)

Automatic switching on of the fan in QUIET mode after the IR motion sensor is activated Detection range from 1 up to 4 m, viewing angle – 100°.

The unit is controlled via a user-friendly remote controller that allows to quickly adjust all the key operating parameters. Users can easily toggle speeds, select operating modes, and fine-tune system settings from anywhere in the room, delivering a seamless blend of convenience, precise control, and easy operation.
Color options

Complement any architectural project or interior scheme with custom decorative panels. Available in a wide range of premium finishes, these panels allow for seamless integration into modern commercial and residential spaces without compromising visual design standards.


Video mounting

Easy installation

The fan can be installed either horizontally or vertically on the wall or ceiling. An adjustable spigot enables installation of the Smart Wi-Fi fan in air ducts with a diameter of 100 or 125 mm.

Compatible Accessories
A range of additional accessories is available to enhance the functionality, control options, and installation efficiency of Blauberg Smart.
FAQ
How is the fan installed?

Preparation & Mounting: Follow the instructions provided with your specific model, which can be found in the product manual (passport) or viewed in the installation video. Units are mounted to a wall or ceiling, either directly into a ventilation shaft or via a flexible duct secured with a clamp.

Connection & Verification: Once fixed with suitable screws, connect the fan to the power grid and verify proper operation across all modes.

Professional Installation: For safety and warranty compliance, electrical connections should be performed by a certified electrician.
What is the difference between Blauberg Smart and Blauberg Smart IR?

The Blauberg Smart IR differs from the standard Blauberg Smart exclusively by the integration of an infrared (IR) motion sensor.

While all other technical specifications, airflow performance, and functional settings remain identical, the IR version automatically triggers ventilation upon detecting movement within its coverage area — offering enhanced automated control for commercial and residential spaces.

How often should the fan be cleaned?

Regular maintenance is recommended to maintain reliable and efficient performance. For residential units like the Blauberg Smart, cleaning should be performed every six months, depending on environmental conditions.

Typical maintenance includes detaching the front cover, carefully cleaning internal surfaces with a soft brush or dry cloth, and rinsing the cover if required. Ensure all components are thoroughly dry before reassembling and restoring power.
Lineup Blauberg Smart Connected air duct size, mm Maximum airflow, m³/h Sound pressure level LpA at 3 m, dB(A) Motion sensor Humidity sensor Timer Number of speeds