Unit of measurement | Sileo Design V2 100 T | ||
Connected air duct size | mm | 100 | |
Minimum supply voltage | V | 220 | |
Maximum supply voltage | V | 240 | |
Power supply frequency | Hz | 50 | |
Rated power | W | 4.5 | 7 |
Unit current | A | 0.029 | 0.052 |
Maximum airflow | m3/h | 60 | 90 |
rotation speed at 50hz | - | 1850 | 2400 |
Sound pressure level LpA at 3 m | dB(A) | 22 | 25 |
Weight | kg | 0.66 | |
Ambient air temperature min | °С | 1 | |
Ambient air temperature max | °С | 40 | |
Ingress protection rating | - | IP45 |
Trademark | Blauberg | |||||
Model | Sileo Design V2 100 T | |||||
Specific energy consumption (SEC) (kWh/(m2/a)) | Cold | Average | Warm | |||
30.9 | B | 14.5 | E | 5.1 | F | |
Type of ventilation unit | Unidirectional | |||||
Type of drive installed | Single speed | |||||
Type of heat recovery system | None | |||||
Maximum flow rate (m3/h) | 90 | |||||
Electric power input (W) | 7.5 | |||||
Reference flow rate (m3/s) | 0.018 | |||||
Specific power input (SPI) (W/(m3/h)) | 0.083 | |||||
Control typology | Manual control | |||||
Maximum external leakage rates (%) | 2.7 | |||||
Sound power level (dB(A)) | 46 | |||||
Declared typology | RVU UVU | |||||
The annual electricity consumption (AEC) (kWh/a) | Cold | Average | Warm | |||
104 | 104 | 104 | ||||
The annual heating saved (AHS) (kWh/a) | Cold | Average | Warm | |||
3355 | 1715 | 776 |
Name | Photo | Description |
---|---|---|
Blauberg CDP-2/10 | Multi-speed switch |