Unit of measurement | Iso-RB 160 | |
Connected air duct size | mm | 160 |
Phases | - | 1 |
Minimum supply voltage | V | 230 |
Maximum supply voltage | V | 230 |
Power supply frequency | Hz | 50 |
Rated power | W | 86 |
Unit current | A | 0.38 |
Maximum airflow | m3/h | 500 |
rotation speed at 50hz | - | 2670 |
Sound pressure level LpA at 3 m | dB(A) | 38 |
Weight | kg | 17 |
Transported air temperature (max) | °С | 55 |
Transported air temperature (min) | °С | -25 |
Ingress protection rating | - | IPX4 |
Ingress protection rating of the drive | - | IP44 |
Trademark | Blauberg | |||||
Model | Iso-RB 160 | |||||
Specific energy consumption (SEC) (kWh/(m2/a)) | Cold | Average | Warm | |||
-51.7 | A+ | -24.6 | C | -9.1 | F | |
Type of ventilation unit | Unidirectional | |||||
Type of drive installed | Variable speed | |||||
Type of heat recovery system | None | |||||
Maximum flow rate (m3/h) | 430 | |||||
Electric power input (W) | 82 | |||||
Reference flow rate (m3/s) | 0.084 | |||||
Reference pressure difference (Pa) | 50 | |||||
Specific power input (SPI) (W/(m3/h)) | 0.278 | |||||
Control typology | Local demand control | |||||
Maximum external leakage rates (%) | 2.7 | |||||
Declared typology | RVU UVU | |||||
Sound power level (dB(A)) | 58 | |||||
The annual electricity consumption (AEC) (kWh/a) | Cold | Average | Warm | |||
147 | 147 | 147 | ||||
The annual heating saved (AHS) (kWh/a) | Cold | Average | Warm | |||
5536 | 2830 | 1280 |
Name | Photo | Description |
---|---|---|
Blauberg CDT E1.8 | Thyristor speed controller | |
Blauberg CDTE E3.0 TP | Speed controllers |
Name | Photo | Description |
---|---|---|
Blauberg TE / TI 1.5 | Timers | |
Blauberg LSE / LSI 1.5 | Sensors | |
Blauberg HSE / HSI 1.5 | Sensors | |
Blauberg IRSE / IRSI 1.5 | Sensors |
Name | Photo | Description |
---|---|---|
Blauberg KFBT 160 G4 | Filter boxes with pocket filters for round ducts | |
Blauberg KFBK 160 | Filter boxes for round ducts | |
Blauberg KFBT 160 F7 | Filter boxes with pocket filters for round ducts | |
Blauberg KFBT 160 F5 | Filter boxes with pocket filters for round ducts |
Name | Photo | Description |
---|---|---|
Blauberg SD 160/1200 | Silencers for round ducts | |
Blauberg SD 160/900 | Silencers for round ducts | |
Blauberg SD 160/600 | Silencers for round ducts |
Name | Photo | Description |
---|---|---|
Blauberg VKA 160 | Air dampers for round ducts | |
Blauberg VRV 160 | Backdraft dampers with spring for round ducts |
Name | Photo | Description |
---|---|---|
Blauberg WKH 160-4 | Duct water heaters for round ducts | |
Blauberg WKH 160-2 | Duct water heaters for round ducts |
Name | Photo | Description |
---|---|---|
Blauberg EKH 160-6.0 | Duct electrical heaters for round ducts | |
Blauberg EKH 160-5.1 | Duct electrical heaters for round ducts | |
Blauberg EKH 160-3.6 | Duct electrical heaters for round ducts | |
Blauberg EKH 160-3.4 | Duct electrical heaters for round ducts | |
Blauberg EKH 160-2.4 | Duct electrical heaters for round ducts | |
Blauberg EKH 160-2.0 | Duct electrical heaters for round ducts | |
Blauberg EKH 160-1.7 | Duct electrical heaters for round ducts | |
Blauberg EKH 160-1.2 | Duct electrical heaters for round ducts |