| Unit of measurement | Freshpoint Eco 160 | |||
| Phases | - | 1 | ||
| Minimum supply voltage | V | 220 | ||
| Maximum supply voltage | V | 240 | ||
| Power supply frequency | Hz | 50/60 | ||
| Rated power | W | 3 | 5 | 8 |
| Unit current | A | 0.02 | 0.03 | 0.04 |
| Air flow in ventilation mode | m3/h | 10 | 30 | 48 |
| Air flow in heat recovery mode | m3/h | 10 | 30 | 48 |
| Sound pressure level LpA at 3 m | dB(A) | 14 | 27 | 40 |
| Sound pressure level LpA at 1 m | dB(A) | 24 | 36 | 50 |
| Heat recovery efficiency, max | % | 92 | ||
| Heat exchanger material | - | Ceramic | ||
| Filter | - | G3 | ||
| Transported air temperature (max) | °С | 50 | ||
| Transported air temperature (min) | °С | -30 | ||
| Ambient air humidity max | % | 70 | ||
| Ingress protection rating | - | IPX4 | ||
| Maximum wall thickness | mm | 440 | ||
| Article | - | 8105852 | ||
| Trademark | Blauberg | |||||
| Model | Freshpoint Eco 160 | |||||
| Specific energy consumption (SEC) (kWh/(m2/a)) | Cold | Average | Warm | |||
| -73.6 | A+ | -35 | A | -12.9 | E | |
| Type of ventilation unit | Bidirectional | |||||
| Type of drive installed | Variable speed | |||||
| Type of heat recovery system | Regenerative | |||||
| Thermal efficiency of heat recovery (%) | 74 | |||||
| Maximum flow rate (m3/h) | 48 | |||||
| Electric power input (W) | 8 | |||||
| Reference flow rate (m3/s) | 0.01 | |||||
| Specific power input (SPI) (W/(m3/h)) | 0.171 | |||||
| Control typology | Local demand control | |||||
| Maximum internal leakage rates (%) | 0.1 | |||||
| Maximum external leakage rates (%) | 0.9 | |||||
| Mixing rate (%) | 1 | |||||
| Airflow sensitivity at +20 Pa and -20 Pa (%) | 1 | |||||
| The indoor/outdoor air tightness (m3/h) | 7 | |||||
| Declared typology | RVU BVU | |||||
| Sound power level (dB(A)) | 46 | |||||
| The annual electricity consumption (AEC) (kWh/a) | Cold | Average | Warm | |||
| 213 | 213 | 213 | ||||
| The annual heating saved (AHS) (kWh/a) | Cold | Average | Warm | |||
| 7893 | 4035 | 1825 | ||||
| Name | Photo | Description |
|---|---|---|
| Blauberg CPSO-200 Freshpoint 160 |
|
External compensator pad |
| Blauberg CPSO-120 Freshpoint 160 |
|
External compensator pad |
| Blauberg CPSO-80 Freshpoint 160 |
|
External compensator pad |
| Blauberg CPSO-160 Freshpoint 160 |
|
External compensator pad |
| Blauberg CPSO-40 Freshpoint 160 |
|
External compensator pad |
| Blauberg MPS Freshpoint 160 |
|
Stainless steel cuff for external installation |
| Blauberg SF Freshpoint G3 |
|
Filter (2 pcs.) |
| Blauberg SF Freshpoint G4 |
|
Filter (2 pcs.) |
| Blauberg SF Freshpoint G4 + carbon |
|
Filter (2 pcs.) |