Saint-Georges, Canada

“Saint-Georges” Multisport Complex

Equipment:

  • 2 Blauberg BlauAIR CFH 2500 air handling units

Completed: June 2023

Area: 7,140 m²

Client: Centre de services scolaire de la Beauce-Etchemin et la Ville de Saint Georges

Architects: ABCP architecture, Marie-Lise Leclerc and Bilodeau Baril Leeming

A Modern Center for Sports and Energy Efficiency

The Multisport Complex in Saint-Georges (Quebec, Canada) is the result of an ambitious project to expand the 1974 high school building. The architectural concept, developed by ABCP Architecture in collaboration with Marie-Lise Leclerc and Bilodeau Baril Leeming, combined energy-efficient architecture, functionality, and a distinctive aesthetic style.  

The new complex covers an area of over 7,100 m² and includes a 10-lane semi-Olympic pool, a recreational pool, two gyms, classrooms, multi-purpose areas, and bleachers seating 250 people. It is a space designed not only for sports but also for the city's community—open, bright, featuring inclusive architecture, and built in compliance with Quebec's current building energy efficiency requirements. 

Stringent ventilation requirements

The primary objective of the complex’s ventilation system was to ensure a stable supply of fresh air and the removal of exhaust air. Considering that the facility is visited by hundreds of people daily, as well as the presence of swimming pools, gyms, and bleachers with varying occupancy levels, the requirements for supply and exhaust ventilation were particularly high. It was necessary to ensure high-quality air exchange in all areas, stable operation under variable loads, and compliance with modern energy efficiency standards.

The project had to be designed in accordance with Chapter I.1 – “Energy Efficiency of Buildings” of the Quebec Building Code and the Canadian National Energy Code for Buildings (2015, as amended). The requirements mandated the use of heat recovery ventilation systems to improve the overall energy performance of buildings in Quebec.

BlauAir CFH 2500: a technological solution from Blauberg
To ensure the project met technical requirements and energy efficiency regulations, two BlauAir CFH 2500 supply and exhaust air handling units were installed, with a combined airflow of 5,000 m³/h (2,940 CFM). The maximum airflow of each unit is 2,850 m³/h, providing the necessary air exchange for swimming pools, gyms, spectator stands, and classrooms. 

The units’ energy efficiency is based on EC fans equipped with an external rotor and backward-curved blades. The rated power of both the supply and exhaust fans is 1,200 W each, and smooth control allows for precise adjustment of air change to accommodate varying loads. For a facility with uneven visitor traffic, this ensures energy savings during periods of low occupancy. The sound pressure level at a distance of 3 m is only 37 dB(A), so the equipment does not interfere with either the educational process or training sessions.

Heat recovery is provided by a highly efficient counterflow plate heat exchanger made of profiled polystyrene plates. Stainless-steel condensate drain pans are installed on both the supply and exhaust sides, which is important for facilities with high humidity. An automatic bypass allows air to bypass the heat exchanger when heat recovery is not required. The units comply with Quebec regulations regarding the mandatory use of heat recovery systems. 

Air filtration is provided by panel filters rated ePM1 70% (ISO 16890) / F7 (EN 779) on both the supply and exhaust sides. The 50-mm-thick casing (class T2/TB2) features hinged service doors that facilitate filter replacement and maintenance. The total weight of the unit is 365 kg. The protection rating is IP22 for the unit and IP54 for the motor. The equipment operates at air temperatures ranging from −25 to +40 °C. 

The integrated Plug & Play control system features a web interface and supports the MODBUS protocol. Control is possible based on humidity, CO₂ levels, temperature, constant pressure, or a schedule. This allows the system to automatically respond to the number of people in the rooms and the air quality. Outputs are provided for additional DX or water-based cooling or heating, as well as a full range of accessories: silencers, economizers, and VAV and CAV systems.

Outcomes and Benefits for the Client

Thanks to a combination of energy-efficient solutions, the complex consumes 20% less energy than a baseline building of the same purpose, according to calculations based on the National Energy Code for Buildings (NECB). Compared to the requirements of previous building codes, the facility’s energy performance exceeds the standard by 23%, placing it in the category of exemplary public buildings in terms of energy efficiency.

Overall, the implementation of Blauberg ventilation systems made it possible not only to meet regulatory standards but also to exceed the client's expectations, creating a benchmark example of a modern sports facility with a safe and comfortable indoor climate supported by heat recovery ventilation.