Intelligent control: Optimize your microclimate with our intelligent integrated control functions, allowing for personalized settings. Choose from a variety of operating modes to achieve the highest level of comfort.
Innovative design: The unique impeller shape and modern DC motor deliver exceptionally low-noise operation at a mere 0.9 dBA, combined with high air flow. The efficiency of the DC motor is noticeable in how it consumes minimal energy, just 2.7 watts even when operating at its highest speed.
Installation options: The fan's high water ingress protection level allows it to be installed over showers. Additionally, compatibility with a DC 12 V power supply makes it possible to be installed on yachts and motorhomes. Select from sophisticated black and white design options to fit any space.
Design:
Practical design: The fan has an IP44 ingress protection rating, allowing it to be installed in Zone 1 of bathrooms. Thanks to replaceable spigots, it is suitable for mounting with Ø100 or Ø125 mm air ducts. The motor unit and impeller are easily removable without the need for special tools.
Color options: Black and white designs are available to integrate the Blauberg O2 fan into your space.
LIGHTING SENSOR
The lighting sensor works autonomously. It collects statistical data about the natural indoor light level and is triggered by an abrupt change in the light level. Daily natural light level changes do not trigger the sensor.
HUMIDITY SENSOR
Humidity sensor autonomously selects the optimum humidity level for the room in which it is installed. The fan's operation algorithm is selected based on analyzing the statistical data of the indoor humidity level.
TIMER
TEMPERATURE SENSOR
It is triggered by a change in indoor air temperature when it reaches 28 °С, and turns off at a temperature of 24 °C.
MOTION SENSOR
It is triggered by detecting motion within its operational zone.
Mode 1
The fan works in permanent ventilation mode at a speed of 20 m3/h; Once the motion sensor is triggered, the fan speed is changed to 60 m3/h, and if the humidity sensor is triggered, the fan operates at 90 m3/h.
Mode 2
The fan works in permanent ventilation mode at a speed of 40 m3/h. Once either the motion sensor or light sensor is triggered, the fan speed is changed to 60 m3/h, and if the humidity sensor is triggered, the fan operates at 90 m3/h.
Mode 3
The fan works in permanent ventilation mode at a speed of 40 m3/h; if the humidity sensor is triggered, the fan speed is changed to 115 m3/h.
Mode 4
The fan works in permanent ventilation mode at a speed of 60 m3/h; if the humidity sensor is triggered, the fan speed is changed to 115 m3/h.
Mode 5
The fan is in standby mode; it is activated by a signal from the triggered motion or lighting sensor and operates at 60 m3/h; if the humidity sensor is triggered, the fan speed changes to 90 m3/h.
Mode 6
The fan works in interval ventilation mode (30 minutes of operation every 12 hours) at a speed of 20 m3/h; if the motion or lighting sensor is triggered, the fan speed is changed to 60 m3/h and if the humidity sensor is triggered, fan speed changes to 90 m3/h.
Mode 7
The fan is in standby mode; if the heat sensor is triggered, the fan speed is changed to 90 m3/h.
Mode 8
The fan is in standby mode; if the humidity sensor is triggered, the fan starts operating at 115 m3/h.
Lineup Blauberg O2 | Connected air duct size, mm | Rated power, W | Maximum airflow, m3/h | Sound pressure level LpA at 3 m, dB(A) | Motion sensor | Humidity sensor | Temperature sensor | Timer |
---|---|---|---|---|---|---|---|---|
100 125 |
2.9 | 140 | 28 | |||||
100 125 |
2.9 | 140 | 28 |