Series Blauberg O2

Blauberg O2 – your solution for intelligent and efficient exhaust ventilation in any space.
  • Motor type: DC
  • Control: Built-in control panel
  • Impeller type: Axial
  • Motion sensor
  • Humidity sensor: Built-in
  • Timer: Turn off timer

Intelligent control: Optimize your microclimate with our intelligent integrated control functions, allowing for personalized settings. Choose from a variety of operating modes to achieve the highest level of comfort.


Innovative design
: The unique impeller shape and modern DC motor deliver exceptionally low-noise operation at a mere 0.9 dBA, combined with high air flow. The efficiency of the DC motor is noticeable in how it consumes minimal energy, just 2.7 watts even when operating at its highest speed.


Installation options
: The fan's high water ingress protection level allows it to be installed over showers. Additionally, compatibility with a DC 12 V power supply makes it possible to be installed on yachts and motorhomes. Select from sophisticated black and white design options to fit any space.


Design
:

  • The fan is equipped with a specially designed motor, featuring ball bearings and an aerodynamically optimized impeller shape, ensures low-noise operation at 9 dBA while maintaining high air flow.
  • Maintenance-free bearings, filled with grease for the entire motor service life, ensure long-term operation.
  • The motor is equipped with overheating protection.


Practical design: The fan has an IP44 ingress protection rating, allowing it to be installed in Zone 1 of bathrooms. Thanks to replaceable spigots, it is suitable for mounting with Ø100 or Ø125 mm air ducts. The motor unit and impeller are easily removable without the need for special tools.




Color options: Black and white designs are available to integrate the Blauberg O2 fan into your space.









Intelligent Sensors in the Blauberg O2 Fan

LIGHTING SENSOR

The lighting sensor works autonomously. It collects statistical data about the natural indoor light level and is triggered by an abrupt change in the light level. Daily natural light level changes do not trigger the sensor.


HUMIDITY SENSOR

Humidity sensor autonomously selects the optimum humidity level for the room in which it is installed. The fan's operation algorithm is selected based on analyzing the statistical data of the indoor humidity level.


TIMER

  • Turn-on delay timer is set at 30 sec. It is triggered by the lighting sensor or humidity sensor.
  • Turn-off delay timer is set at 15 minutes and is always triggered by a motion, lighting or humidity sensor.


TEMPERATURE SENSOR

It is triggered by a change in indoor air temperature when it reaches 28 °С, and turns off at a temperature of 24 °C.


MOTION SENSOR

It is triggered by detecting motion within its operational zone.

OPERATION MODES
The Blauberg O2 fan operation modes can be selected using a multiposition switch on the motor unit.

Mode 1
The fan works in permanent ventilation mode at a speed of 20 m3/h; Once the motion sensor is triggered, the fan speed is changed to 60 m3/h, and if the humidity sensor is triggered, the fan operates at 90 m3/h.


Mode 2
The fan works in permanent ventilation mode at a speed of 40 m3/h. Once either the motion sensor or light sensor is triggered, the fan speed is changed to 60 m3/h, and if the humidity sensor is triggered, the fan operates at 90 m3/h.

Mode 3
The fan works in permanent ventilation mode at a speed of 40 m3/h; if the humidity sensor is triggered, the fan speed is changed to 115 m3/h.


Mode 4
The fan works in permanent ventilation mode at a speed of 60 m3/h; if the humidity sensor is triggered, the fan speed is changed to 115 m3/h.

Mode 5
The fan is in standby mode; it is activated by a signal from the triggered motion or lighting sensor and operates at 60 m3/h; if the humidity sensor is triggered, the fan speed changes to 90 m3/h.

Mode 6
The fan works in interval ventilation mode (30 minutes of operation every 12 hours) at a speed of 20 m3/h; if the motion or lighting sensor is triggered, the fan speed is changed to 60 m3/h and if the humidity sensor is triggered, fan speed changes to 90 m3/h.

Mode 7
The fan is in standby mode; if the heat sensor is triggered, the fan speed is changed to 90 m3/h.

Mode 8
The fan is in standby mode; if the humidity sensor is triggered, the fan starts operating at 115 m3/h.

Lineup Blauberg O2 Connected air duct size, mm Rated power, W Maximum airflow, m3/h Sound pressure level LpA at 3 m, dB(A) Motion sensor Humidity sensor Temperature sensor Timer
100
125
2.9 140 28
100
125
2.9 140 28
Datasheet
O2 & O2 Supreme - data sheet
1.17 Mb
Manual
O2 & O2 Supreme - user's manual (B255EN-02)
3.5 Mb
Image
O2 & O2 Supreme
424 Kb
Image
O2 Supreme - image
724 Kb
Image
O2 Supreme - image
224 Kb
Image
O2 Supreme - image
248 Kb
Image
O2 Supreme - image
729 Kb
Image
O2 Supreme - image
756 Kb
Image
O2 Supreme - image
579 Kb