Blauberg Tower-HC 310 2E

Roof centrifugal fans
  • Maximum airflow: 2150 m3/h
  • Sound pressure level LpA at 3 m: 58 dB(A)
  • Motor type: AC
  • Impeller type: Centrifugal backward curved blades
  • Casing material: Coated steel
Unit of measurement Tower-HC 310 2E
Phases - 1
Minimum supply voltage V 230
Maximum supply voltage V 230
Power supply frequency Hz 50
Rated power W 324
Unit current A 1.42
Maximum airflow m3/h 2150
rotation speed at 50hz - 2620
Sound pressure level LpA at 3 m dB(A) 58
Weight kg 10
Transported air temperature (max) °С 50
Transported air temperature (min) °С -25
Ingress protection rating - IPX4
Ingress protection rating of the drive - IP44
Trademark Blauberg
Model Tower-HC 310 2E
Type of drive installed External MSD or VSD
Type of heat recovery system None
Nominal flow rate (m3/s) 0.381
Nominal external pressure (Pa) 254
Maximum external leakage rates (%) 2.7
Static efficiency (%) 32.6
Effective electric power input (kW) 0.303
Sound power level (dB(A)) 78
Declared typology NRVU UVU
Datasheet
Tower-HC - data sheet
519 Kb
Manual
TOWER-HC - user's manual (B204-2EN-02)
2.05 Mb
Image
Tower-HC 310 2E - image 1
392 Kb
H ∅D ∅D1 L L1
258 623 285 420 330