Unit of measurement | Sileo V2 100 | ||
Connected air duct size | mm | 100 | |
Minimum supply voltage | V | 220 | |
Maximum supply voltage | V | 240 | |
Power supply frequency | Hz | 50/60 | |
Rated power | W | 4.5 | 7 |
Unit current | A | 0.029 | 0.052 |
Maximum airflow | m3/h | 60 | 90 |
Sound pressure level LpA at 3 m | dB(A) | 22 | 25 |
Weight | kg | 0.55 | |
Ambient air temperature min | °С | 1 | |
Ambient air temperature max | °С | 45 | |
Ingress protection rating | - | IP45 |
Trademark | Blauberg | |||||
Model | Sileo V2 100 | |||||
Specific energy consumption (SEC) (kWh/(m2/a)) | Cold | Average | Warm | |||
-31.2 | B | -14.8 | E | -5.4 | F | |
Type of ventilation unit | Unidirectional | |||||
Type of drive installed | 2-speed | |||||
Type of heat recovery system | None | |||||
Maximum flow rate (m3/h) | 90 | |||||
Electric power input (W) | 7 | |||||
Reference flow rate (m3/s) | 0.017 | |||||
Specific power input (SPI) (W/(m3/h)) | 0.075 | |||||
Control typology | Manual control | |||||
Maximum external leakage rates (%) | 2.7 | |||||
Declared typology | RVU UVU | |||||
Sound power level (dB(A)) | 42 | |||||
The annual electricity consumption (AEC) (kWh/a) | Cold | Average | Warm | |||
94 | 94 | 94 | ||||
The annual heating saved (AHS) (kWh/a) | Cold | Average | Warm | |||
3355 | 1715 | 776 |