Blauberg Line 125

Extract fans
  • Maximum airflow: 180 m3/h
  • Sound pressure level LpA at 3 m: 35 dB(A)
  • Motor type: AC
  • Casing material: Plastic
  • Pull cord
  • Humidity sensor
  • Timer: Turn off timer
Unit of measurement Line 125
Connected air duct size mm 125
Minimum supply voltage V 220
Maximum supply voltage V 240
Power supply frequency Hz 50
Rated power W 16
Unit current A 0.1
Maximum airflow m3/h 180
Sound pressure level LpA at 3 m dB(A) 35
Weight kg 0.74
Ambient air temperature min °С 1
Ambient air temperature max °С 40
Ingress protection rating - IP34
Trademark Blauberg
Model Line 125
Specific energy consumption (SEC) (kWh/(m2/a)) Cold Average Warm
-32 B -15 E -6 F
Type of ventilation unit Unidirectional
Type of drive installed Multi-speed
Type of heat recovery system None
Maximum flow rate (m3/h) 180
Electric power input (W) 16
Reference flow rate (m3/s) 0.035
Specific power input (SPI) (W/(m3/h)) 0.057
Control typology Manual control
Maximum external leakage rates (%) 2.7
Declared typology RVU UVU
Sound power level (dB(A)) 55
The annual electricity consumption (AEC) (kWh/a) Cold Average Warm
100 100 100
The annual heating saved (AHS) (kWh/a) Cold Average Warm
3400 1700 800
Datasheet
Line - data sheet
640 Kb
Manual
Line - user's manual (B220EN-02)
2.11 Mb
BIM/CAD models
Line
1.09 Mb
Image
Line 125 - image 1
640 Kb
a b c ∅ d e
176 140 114 125 12.5
Name Photo Description
Blauberg CDT E1.8 CDT E1.8 Thyristor speed controller