Unit of measurement | Line 100 H | |
Connected air duct size | mm | 100 |
Minimum supply voltage | V | 220 |
Maximum supply voltage | V | 240 |
Power supply frequency | Hz | 50/60 |
Rated power | W | 14 |
Unit current | A | 0.085 |
Maximum airflow | m3/h | 95 |
Sound pressure level LpA at 3 m | dB(A) | 34 |
Weight | kg | 0.58 |
Ambient air temperature min | °С | 1 |
Ambient air temperature max | °С | 40 |
Ingress protection rating | - | IP34 |
Trademark | Blauberg | |||||
Model | Line 100 H | |||||
Specific energy consumption (SEC) (kWh/(m2/a)) | Cold | Average | Warm | |||
-53.4 | A+ | -26.4 | B | -10.9 | E | |
Type of ventilation unit | Unidirectional | |||||
Type of drive installed | Multi-speed | |||||
Type of heat recovery system | None | |||||
Maximum flow rate (m3/h) | 95 | |||||
Electric power input (W) | 14 | |||||
Reference flow rate (m3/s) | 0.018 | |||||
Specific power input (SPI) (W/(m3/h)) | 0.095 | |||||
Control typology | Local demand control | |||||
Maximum external leakage rates (%) | 2.7 | |||||
Declared typology | RVU UVU | |||||
Sound power level (dB(A)) | 54 | |||||
The annual electricity consumption (AEC) (kWh/a) | Cold | Average | Warm | |||
77 | 77 | 77 | ||||
The annual heating saved (AHS) (kWh/a) | Cold | Average | Warm | |||
5536 | 2830 | 1280 |