Unit of measurement | Iso-B 200 max | |
Connected air duct size | mm | 200 |
Minimum supply voltage | V | 220 |
Maximum supply voltage | V | 240 |
Power supply frequency | Hz | 50/60 |
Rated power | W | 195 |
Unit current | A | 0.85 |
Maximum airflow | m3/h | 950 |
Sound pressure level LpA at 3 m | dB(A) | 41 |
Weight | kg | 12 |
Transported air temperature (max) | °С | 45 |
Transported air temperature (min) | °С | -25 |
Ingress protection rating | - | IPX4 |
Trademark | Blauberg | |||||
Model | Iso-B 200 max | |||||
Specific energy consumption (SEC) (kWh/(m2/a)) | Cold | Average | Warm | |||
-53.1 | A+ | -26 | B | -10.5 | E | |
Type of ventilation unit | Unidirectional | |||||
Type of drive installed | Variable speed | |||||
Type of heat recovery system | None | |||||
Maximum flow rate (m3/h) | 900 | |||||
Electric power input (W) | 195 | |||||
Reference flow rate (m3/s) | 0.175 | |||||
Reference pressure difference (Pa) | 50 | |||||
Specific power input (SPI) (W/(m3/h)) | 0.17 | |||||
Control typology | Local demand control | |||||
Maximum external leakage rates (%) | 2.7 | |||||
Declared typology | RVU UVU | |||||
Sound power level (dB(A)) | 41 | |||||
The annual electricity consumption (AEC) (kWh/a) | Cold | Average | Warm | |||
90 | 90 | 90 | ||||
The annual heating saved (AHS) (kWh/a) | Cold | Average | Warm | |||
5536 | 2830 | 1280 |
Name | Photo | Description |
---|---|---|
Blauberg CDT E1.8 | Thyristor speed controller |
Name | Photo | Description |
---|---|---|
Blauberg TE / TI 1.5 | Timers | |
Blauberg HSE / HSI 1.5 | Sensors | |
Blauberg LSE / LSI 1.5 | Sensors | |
Blauberg IRSE / IRSI 1.5 | Sensors |