Blauberg Freshpoint Eco 160 L1

Smart HRV unit for single-room ventilation
  • Air flow in heat recovery mode: 48 m3/h
  • Sound pressure level LpA at 3 m: 40 dB(A)
  • Sound pressure level LpA at 1 m: 50 dB(A)
  • Filter: G3
  • Motor type: EC
  • Control: Remote Control
  • Casing material: ABS Plastic
  • Temperature sensor
Unit of measurement Freshpoint Eco 160 L1
Phases - 1
Minimum supply voltage V 220
Maximum supply voltage V 240
Power supply frequency Hz 50/60
Rated power W 3 5 8
Unit current A 0.02 0.03 0.04
Maximum airflow m3/h
Air flow in ventilation mode m3/h 10 30 48
Air flow in heat recovery mode m3/h 10 30 48
Sound pressure level LpA at 3 m dB(A) 14 27 40
Sound pressure level LpA at 1 m dB(A) 24 36 50
Heat recovery efficiency, max % 92
Heat exchanger material - Ceramic
Filter - G3
Transported air temperature (max) °С 50
Transported air temperature (min) °С -30
Ambient air humidity max % 70
Ingress protection rating - IPX4
Trademark Blauberg
Model Freshpoint Eco 160 L1
Specific energy consumption (SEC) (kWh/(m2/a)) Cold Average Warm
81.2 A+ 40 A 16.4 E
Type of ventilation unit Bidirectional
Type of drive installed Variable speed
Type of heat recovery system Regenerative
Thermal efficiency of heat recovery (%) 74
Maximum flow rate (m3/h) 48
Electric power input (W) 8
Reference flow rate (m3/s) 0.01
Specific power input (SPI) (W/(m3/h)) 0.2
Control typology Local demand control
Maximum internal leakage rates (%) 0.1
Maximum external leakage rates (%) 0.9
Mixing rate (%) 1
Airflow sensitivity at +20 Pa and -20 Pa (%) 0.93
The indoor/outdoor air tightness (m3/h) 7
Sound power level (dB(A)) 46
Declared typology RVU BVU
The annual electricity consumption (AEC) (kWh/a) Cold Average Warm
116 116 116
The annual heating saved (AHS) (kWh/a) Cold Average Warm
84 43 19
Datasheet
Freshpoint Eco - data sheet
1.3 Mb
Manual
Freshpoint Eco - user's manual (B271EN-02)
4.37 Mb
Image
Freshpoint Eco 160 L1 - image 1
431 Kb
ØD L L1
162 1100 1000