Blauberg Auto 150 ST

Extract fans
  • Maximum airflow: 295 m3/h
  • Sound pressure level LpA at 3 m: 39 dB(A)
  • Motor type: AC
  • Pull cord
  • Timer: Turn off timer
Unit of measurement Auto 150 ST
Connected air duct size mm 150
Minimum supply voltage V 220
Maximum supply voltage V 240
Power supply frequency Hz 50
Rated power W
Unit current A 0.13
Maximum airflow m3/h 295
Sound pressure level LpA at 3 m dB(A) 39
Ingress protection rating - IP24
Trademark Blauberg
Model Auto 150 ST
Specific energy consumption (SEC) (kWh/(m2/a)) Cold Average Warm
32 B 15 E 6 F
Type of ventilation unit Unidirectional
Type of drive installed Multi-speed
Type of heat recovery system None
Maximum flow rate (m3/h) 295
Electric power input (W) 26
Reference flow rate (m3/s) 0.057
Specific power input (SPI) (W/(m3/h)) 0.057
Control typology Manual control
Maximum external leakage rates (%) 2.7
Sound power level (dB(A)) 59
Declared typology RVU UVU
The annual electricity consumption (AEC) (kWh/a) Cold Average Warm
100 100 100
The annual heating saved (AHS) (kWh/a) Cold Average Warm
3400 1700 800
Datasheet
Auto - data sheet
635 Kb
Manual
Auto - user's manual (AUTO_EN-03)
1.96 Mb
BIM/CAD models
Auto
1.55 Mb
Certificates
Auto - certificate LVD
274 Kb
Image
Auto 150 ST - image 1
422 Kb
a b1 b2 b3 c ∅ d e
210 150 195 196 115 150 34