| Unit of measurement | Sileo DC 100 H | ||
| Speed | - | 1 | 2 |
| Connected air duct size | mm | 100 | |
| Minimum supply voltage | V | 220 | |
| Maximum supply voltage | V | 240 | |
| Power supply frequency | Hz | 50/60 | |
| Rated power | W | 1.5 | 3.5 |
| Unit current | A | 0.063 | 0.137 |
| Maximum airflow | m3/h | 70 | 101 |
| Sound pressure level LpA at 3 m | dB(A) | 22 | 27 |
| Weight | kg | 0.55 | |
| Ambient air temperature min | °С | 1 | |
| Ambient air temperature max | °С | 40 | |
| Ingress protection rating | - | IP45 | |
| Impeller material | - | Plastic | |
| Article | - | 8044601 | |
| Trademark | Blauberg | |||||
| Model | Sileo DC 100 H | |||||
| Specific energy consumption (SEC) (kWh/(m2/a)) | Cold | Average | Warm | |||
| -55 | A+ | -27.9 | B | -12.4 | E | |
| Type of ventilation unit | Unidirectional | |||||
| Type of drive installed | 2-speed | |||||
| Type of heat recovery system | None | |||||
| Maximum flow rate (m3/h) | 101 | |||||
| Electric power input (W) | 3.5 | |||||
| Reference flow rate (m3/s) | 0.019 | |||||
| Specific power input (SPI) (W/(m3/h)) | 0.021 | |||||
| Control typology | Local demand control | |||||
| Maximum external leakage rates (%) | 2.7 | |||||
| Declared typology | RVU UVU | |||||
| Sound power level (dB(A)) | 47 | |||||
| The annual electricity consumption (AEC) (kWh/a) | Cold | Average | Warm | |||
| 16 | 16 | 16 | ||||
| The annual heating saved (AHS) (kWh/a) | Cold | Average | Warm | |||
| 5536 | 2830 | 1280 | ||||