Blauberg Line 150 T

Extract fans
  • Sound pressure level LpA at 3 m: 38 dB(A)
  • Casing material: Plastic
  • Timer: Turn off timer
Unit of measurement Line 150 T
Connected air duct size mm 150
Minimum supply voltage V 220
Maximum supply voltage V 240
Power supply frequency Hz 50
Rated power W 24
Unit current A 0.13
Maximum airflow m³/h 292
Sound pressure level LpA at 3 m dB(A) 38
Weight kg 0.92
Ambient air temperature min °С 1
Ambient air temperature max °С 40
Ingress protection rating - IP34
Impeller material - Plastic
Article - 8008191
Trademark Blauberg
Model Line 150 T
Specific energy consumption (SEC) (kWh/(m²/a)) Cold Average Warm
-35.1 A -17.2 E -6.9 F
Type of ventilation unit Unidirectional
Type of drive installed Multi-speed
Type of heat recovery system None
Maximum flow rate (m³/h) 292
Electric power input (W) 24
Reference flow rate (m³/s) 0.057
Specific power input (SPI) (W/(m³/h)) 0.053
Control typology Clock control
Maximum external leakage rates (%) 2.7
Declared typology RVU UVU
Sound power level (dB(A)) 58
The annual electricity consumption (AEC) (kWh/a) Cold Average Warm
61 61 61
The annual heating saved (AHS) (kWh/a) Cold Average Warm
3667 1874 848
Datasheet
Line - data sheet
640 Kb
Manual
Line - user's manual (B220EN-02)
2.11 Mb
BIM/CAD-models
Line
1.09 Mb
Image
Line 150 T - image 1
640 Kb
a b c ∅ d e
205 165 132 150 13