| Unit of measurement | Ducto Plus 150 | ||
| Speed | - | 1 | 2 |
| Minimum supply voltage | V | 220 | |
| Maximum supply voltage | V | 240 | |
| Power supply frequency | Hz | 50 | |
| Rated power | W | 19 | 22 |
| Unit current | A | 0.087 | 0.095 |
| Maximum airflow | m3/h | 250 | 335 |
| Sound pressure level LpA at 3 m | dB(A) | 36 | 39 |
| Weight | kg | 1.3 | |
| Ambient air temperature min | °С | 1 | |
| Ambient air temperature max | °С | 40 | |
| Ingress protection rating | - | IPX4 | |
| Impeller material | - | Plastic | |
| Article | - | 8001192 | |
| Trademark | Blauberg | |||||
| Model | Ducto Plus 150 | |||||
| Specific energy consumption (SEC) (kWh/(m2/a)) | Cold | Average | Warm | |||
| -31.2 | B | -14.8 | E | -5.4 | F | |
| Type of ventilation unit | Unidirectional | |||||
| Type of drive installed | 2-speed | |||||
| Type of heat recovery system | None | |||||
| Maximum flow rate (m3/h) | 340 | |||||
| Electric power input (W) | 22 | |||||
| Reference flow rate (m3/s) | 0.069 | |||||
| Specific power input (SPI) (W/(m3/h)) | 0.076 | |||||
| Control typology | Manual control | |||||
| Maximum external leakage rates (%) | 2.7 | |||||
| Declared typology | RVU UVU | |||||
| Sound power level (dB(A)) | 56 | |||||
| The annual electricity consumption (AEC) (kWh/a) | Cold | Average | Warm | |||
| 95 | 95 | 95 | ||||
| The annual heating saved (AHS) (kWh/a) | Cold | Average | Warm | |||
| 3355 | 1715 | 776 | ||||